GD2000D Insulation Resistance Tester
Penguji resistensi insulasi digital GD2000D sing diprodhuksi dening perusahaan kita nggunakake sistem operasi real-time chip tunggal industri sing dipasang.Pitunjuk analog digital lan tampilan kode lapangan digital digabungake kanthi sampurna.Seri meter iki nduweni macem-macem tingkat output voltase (250V, 500V, 1000V, 2500V, 5000V, 10000V), kapasitas gedhe, anti-gangguan sing kuat, penunjuk analog lan tampilan sinkron digital, AC lan DC dual-nggunakake, operasi prasaja, pitungan otomatis saka macem-macem pratondho jampel (rasio panyerepan, indeks polarisasi), macem-macem asil pangukuran karo fungsi anti-daya-mudhun, etc. Iku instrument test becik kanggo ngukur resistance jampel saka gedhe-kapasitas trafo, trafo, generator, dhuwur- motor voltase, kapasitor daya, kabel daya, lan penahan kilat.
DL/T 474-2006 "Pandhuan kanggo tes Insulasi ing situs"
DL/T 845-2004 "Spesifikasi umum kanggo peralatan pangukuran resistensi"
DL/T 846-2004 "Spesifikasi teknis umum kanggo peralatan uji tegangan dhuwur"
DL/T 596-2005 "Kode tes pencegahan kanggo peralatan listrik"
GB50150-2006 "Standar kanggo tes serah terima peralatan listrik teknik instalasi peralatan listrik"
GB/T16927.1~2-1997 "Teknik tes voltase dhuwur"
GB4793-1984 "Koordinasi insulasi kanggo peralatan transmisi lan distribusi tegangan dhuwur"
1. Output voltase (250V / 500V / 1000V / 2500V / 5000V).Resistansi sawetara 0-200GΩ.
2. Loro mode tampilan resistance jampel.
3. rasio panyerepan otomatis lan indeks polarisasi.
4. operasi Friendly, nyimpen terus 19times asil pangukuran.
5. Auto-discharge ampas voltase dhuwur sawise test liwat.
6. Sumber daya AC / DC, kanthi baterei sing bisa diisi ulang utawa adaptor AC.
7. Kemampuan anti-gangguan sing kuat, maca stabil lan dipercaya.
8. Desain portabel, cocok kanggo karya alam bébas.
9. Short-circuit saiki ≥3mA, peralatan becik kanggo testing resistance jampel saka trafo gedhe, induktor, generator, motor HV, kapasitor listrik, kabel lan arrester lonjakan.
Item No. | GD2000D | ||||||
Tegangan output | 250 V DC | 500 V DC | 1000 V DC | 2500 V DC | 5000V DC | ||
Akurasi | Suhu | 23 ℃ ± 5 ℃ | |||||
Resistance insulasi | 250-5G ±5% | 50-10G ±5% | 1M-20G ±5% | 2,5M-50G ±5% | 5M-100G ±5% | ||
Kisaran liyane: ± 10% | |||||||
Tegangan output | 2M-10G ±5% | 4M-20G ±5% | 8M-40G 0--+10% | 20-100GΩ 0 --+10% | 40-200G 0-- +10% | ||
Sarus hort-circuit | ≥3mA | ||||||
sumber daya | 8*Baterei sing bisa diisi ulang lan adaptor eksternal jinis AA | ||||||
Suhu Kerja & Kelembapan | -10 ℃--40 ℃, maks. asor relatif 85% | ||||||
Suhu panyimpenan & Kelembapan | -20 ℃--60 ℃, maks. asor relatif 90% | ||||||
Isolasi | Max.2000MΩ nalika voltase antarane sirkuit lan Nihan punika 1000VDC. | ||||||
Tahan voltase | Tahan 1min nalika voltase antarane sirkuit lan cangkang3kVSinus 50Hztegangan AC | ||||||
ukuran | 230mm * 190mm * 90mm (L * W * H) | ||||||
Bobot | 3 kg |
Insulation resistance tester | 1 set |
Test kawat | 1 bêsik |
adaptor daya | 1 bêsik |
kabel daya | 1 bêsik |
Pandhuan pangguna | 1 salinan |
Sertifikat | 1 salinan |